Fulfill the role with confidence.
You know the five tasks under Art. 15 para. 3, from the conformity check before release through documentation to reporting obligations.
Popular: document control, audit management, pricing
As the person responsible for regulatory compliance under Art. 15 MDR/IVDR, you take on a central regulatory role. In eight online modules, you learn the tasks, qualification requirements and interfaces, from product release to vigilance.
The training links the tasks of the PRRC to concrete workflows. In eQMS, you can then store your qualification and appointment in a traceable way.
You know the five tasks under Art. 15 para. 3, from the conformity check before release through documentation to reporting obligations.
The self-paced course starts at any time. You set your own pace and test your knowledge at the end of each module.
You can store the certificate, proof of qualification and appointment in eQMS and quickly find them again when needed.
Whether regulatory affairs, quality management or deputy role: understanding the legal role is the foundation for reliable staffing in the company.
You learn the legal basis, the required qualification profile and the tasks from the ground up.
This way, the company can call on another qualified person. Our partner recommends at least two appropriately qualified people.
You add the tasks provided for in Art. 15 of the MDR and IVDR to your knowledge of vigilance and reporting.
Good to know: The course provides the knowledge for the role. You bring the qualification under Art. 15 para. 1 with you, and your employer makes the appointment.
From the regulatory framework and product requirements to reporting. Each module ends with a knowledge test.
Understanding the role and classifying medical devices
European and German medical device law, requirements from the MDR and IVDR, the role at a glance.
Afterwards, you can: classify relevant regulations and know where the role is anchored.
Who must appoint under Art. 15, required qualification, tasks and the rule for micro and small enterprises.
Afterwards, you can: check your qualification requirements and put your responsibility into context.
Basic safety and performance requirements, terms and distinction from medicinal products.
Afterwards, you can: classify products and name the requirements before release.
Terms, use and examples from the field of in vitro diagnostics.
Afterwards, you can: classify the special features of IVDs and the IVDR.
Risk classes, release, labeling and vigilance
Criteria of the risk classes for medical devices and IVDs, with examples.
Afterwards, you can: understand and justify the classification of your products.
Procedures by risk class, technical documentation and EU declaration of conformity.
Afterwards, you can: name the checkpoints before product release (tasks a and b).
CE marking, graphic symbols and the UDI system.
Afterwards, you can: assess what matters for labeling and UDI.
Post-market surveillance, vigilance, incidents, trends, field safety corrective actions, market surveillance, reporting channels and deadlines.
Afterwards, you can: organize the processes for surveillance and timely reporting (tasks c and d).
You will find task e, the statement for investigational devices, below under the five core tasks of the PRRC. After the last module is successfully completed, you receive the certificate "Person responsible for regulatory compliance under Art. 15 MDR/IVDR" by email.
A preview of key course topics: qualification, IVDR, classification, conformity assessment, UDI and vigilance.
View our partner's course pageUniversity degree or a course of study recognized as equivalent in law, medicine, pharmacy, engineering or another relevant scientific field, plus one year of professional experience in regulatory affairs or QM systems for medical devices.
Professional experience in regulatory affairs or QM systems for medical devices.
MDR Manufacturers of custom-made devices can also count two years of professional experience in the relevant manufacturing area.
Both regulations govern the person responsible for regulatory compliance in Article 15.
Examples The rules are in Annex VIII of the MDR, and for IVDs in Annex VIII of the IVDR with classes A to D.
Task a Before release, the PRRC ensures that conformity has been checked in line with the QM system.
The Basic UDI-DI appears in the technical documentation, in the EU declaration of conformity and in EUDAMED.
Tasks c and d The PRRC ensures that surveillance and reporting obligations are met.
These areas of responsibility must be covered reliably in the company. Suitable colleagues can also carry out the tasks, as long as the PRRC's responsibilities are clearly defined.
If several people share responsibility, the areas of responsibility are set out in writing under Art. 15 para. 4.
MDR · Art. 15 IVDR · Art. 15 MDCG 2019-7
Ensure that the conformity of products is appropriately checked in line with the QM system before release. In the course: Module 6
Ensure that the technical documentation and the EU declaration of conformity are drawn up and kept up to date. In the course: Module 6
Ensure that the post-market surveillance obligations are met (MDR Art. 10 para. 10, IVDR Art. 10 para. 9). In the course: Module 8
Ensure that the reporting obligations are met, for example for serious incidents, field safety corrective actions and trends (MDR Art. 87 to 91, IVDR Art. 82 to 86). In the course: Module 8
Ensure that the required statement is issued for investigational devices (MDR Annex XV Chapter II Section 4.1). Under the IVDR, this applies to devices for interventional and other risk-bearing performance studies (Annex XIV Section 4.1).
The most important questions on appointment, staffing and responsibility, summarized concisely.
Manufacturers must have at least one sufficiently qualified PRRC in their organization. Authorized representatives must have permanent and continuous access to a qualified person.
Art. 15 para. 1 names two ways to demonstrate the required expertise:
Under the MDR, manufacturers of custom-made devices can also count two years of professional experience in the relevant manufacturing field. The IVDR does not include this special rule.
The obligation has applied since May 26, 2021 under the MDR and since May 26, 2022 under the IVDR. Every manufacturer has at least one PRRC in its organization (para. 1), every authorized representative can permanently and continuously call on one (para. 6), and every legal manufacturer needs its own, including within a corporate group (MDCG 2019-7). This also applies to importers and distributors who take on the manufacturer's obligations under Art. 16.
The manufacturer provides the name, address and contact details of the PRRC when registering as an economic operator in EUDAMED (MDR Art. 31 and Annex VI Part A). If the details change, the manufacturer updates them within one week (Art. 31 para. 4). The company keeps appointment letters and proof of qualification in its QM system.
Knowledge of vigilance and reporting is a good foundation for the new role. The training mainly adds what came with the MDR: conformity assessment, technical documentation and the EU declaration of conformity.
An external PRRC meets the legal requirements and is permanently and continuously available to each company. A contract governs availability and qualification. The PRRC can work for several manufacturers if they perform the tasks for each one. A manufacturer and an authorized representative each have their own PRRC.
Legal basis: Art. 15 of Regulation (EU) 2017/745 (MDR) and Regulation (EU) 2017/746 (IVDR), plus the EU guidance MDCG 2019-7.
When preparing for an audit or an inspection by authorities, it is quickly clear who holds the PRRC role, who acts as deputy, and which qualification and training records are on file.
The training itself takes place on our partner's learning platform. eQMS then serves as the repository and QM system for your own records.
Try for freeIn eQMS, you bring your certificate, proof of qualifications and appointment together in a structured way.
You request the PRRC training from eQMS. We coordinate access to the online course and the invoice with our partner.
You send us the number of participants and tell us whether you are an eQMS customer.
You receive the invoice and login details for our partner's learning platform.
Eight modules, about five to six hours, with a knowledge test for each module.
After you complete the course successfully, you receive the certificate by email and can store it in the Qualification module of eQMS.
We offer this training together with our partner Trautmann Managementsysteme. The partner develops the content, runs the online course on its learning platform, and issues the certificate.
Around medical devices there are three roles, each with its own legal basis, and for each of them we offer the matching partner training.
For field sales, inside sales, and product specialists of medical device manufacturers and distributors.
Learn more § 6 MPBetreibVFor healthcare facilities with regularly more than 20 employees, such as hospitals, practices, medical care centers and care providers.
Learn moreWe offer the online course together with our partner Trautmann Managementsysteme. You start whenever it suits you.
339 €excl. VAT
per participant
Who it is for: future persons responsible for regulatory compliance and deputies at manufacturers and authorized representatives, former safety officers, and professionals from regulatory affairs, QM and clinical affairs.
Content: Medical device law, MDR and IVDR · Qualification and responsibilities under Art. 15 · Classification, conformity, CE and UDI · Market surveillance, post-market surveillance and vigilance. View all eight modules
Request training288,15 €for eQMS customers
instead of €339, excl. VAT per participant
15 percent off the course price. To get it, check "We are an eQMS customer" in the inquiry form.
from 10participants
Special terms on request, optionally as a subscription or with your own learning platform for your company.
On request
For on-site training for your team, our partner adapts the content. We will agree on the details with you.
Short answers on the role, qualification, certificate, costs and documentation.
Ask another questionThe PRRC training is an online course with eight modules on the role of the person responsible for regulatory compliance under Art. 15 MDR/IVDR (Person Responsible for Regulatory Compliance), offered by eQMS together with our partner Trautmann Managementsysteme. In five to six hours, participants learn who must appoint a PRRC, what qualification Art. 15 para. 1 requires, and which five tasks the PRRC is responsible for under Art. 15 para. 3, from conformity checks before release to surveillance and reporting obligations. The training provides the knowledge for the role, while participants bring the qualification under Art. 15 para. 1 with them. The course starts anytime, ends with a certificate and costs €339 excl. VAT per participant.
PRRC stands for Person Responsible for Regulatory Compliance, the person responsible for compliance with regulatory requirements under Art. 15 MDR/IVDR. Manufacturers have at least one qualified person responsible in their organization, and authorized representatives must have permanent and continuous access to such a person. A special rule applies to micro and small enterprises.
You become a PRRC when your employer appoints you, and you bring the qualification under Art. 15 para. 1 MDR/IVDR for this. The training provides the knowledge and confirms it with a certificate after successful completion.
Micro and small enterprises may fill the role externally, with a contract covering availability and qualification. The external PRRC is permanently and continuously reachable and can work for several manufacturers if they perform the tasks for each one. For larger manufacturers, the PRRC is an employee of the organization itself according to the EU guidance MDCG 2019-7.
Eight online modules as a self-paced course, about five to six hours in total. The course costs €339 excl. VAT per participant, certificate included. eQMS customers receive 15 percent off the course price, which makes €288.15 excl. VAT. For 10 or more participants, special terms are available on request.
"Qualified Person" is often used in the medical device sector as another name for the PRRC. In pharmaceutical law, however, Qualified Person means a different legal role, the person with expert knowledge (Sachkundige Person).
The medical device safety officer under Section 6 MPBetreibV (German Medical Devices Operator Ordinance) applies to operators, such as hospitals or practices. The PRRC under Art. 15 MDR/IVDR is the regulatory role at manufacturers and authorized representatives.
Yes. You can store training and qualification records in the Qualification module. Appointment letters and documented responsibilities belong in document control, for example.
Tell us how many people want to take part and whether you are already an eQMS customer. We will handle registration and terms with our training partner.